Dental problems and solution (Handpiece)

Contemporary high-speed dental handpiece (that is actually, the turbine head) tend to be driven by gas-driven as well as high-speed rotary bur in order to cutting teeth. Speed and accuracy pressurized at rated rotation straight affects the dentist's medical results. rated rotation speed underneath the pressure the higher the greater concentricity sleeve, the much more accurate the drilling region, the dentist more very easily, while the lower degree of the patient's pain. Thus the dental handpiece in the rated pressure of the actual rotation speed is normal or not is specially important. Dentists often put across a brand new dental bur do not really move the needle nevertheless drilling teeth, while it's normally driven by atmosphere pressure. So the user is generally by adjusting the air pressure in route to get a higher speed to obtain a good cutting result. Actually, it indicates a possible failure, the more pressure the larger the adjustment speed elevated damage tohandpiece will eventually result in undesired cutting effect regardless of how high the air pressure cannot achieve. So we must replace the handset due to damage to the teeth from the dental drill is utilized; the impact of it's internal bearing life element in "fatigue life" and "grease life" may be the most prominent. Therefore, within the usual course of the next three points should end up being noted:

1. Two high-speed dental care handpiece used interchangeably
bearing in use is a high speed rotating, ball bearing then kept informed to exert force towards the bearing inner ring, using the bearing over time will result in a "mechanical fatigue", and therefore directly affect the showing life. Dentists usually make use of standard treatment table, along with two high-speed dental handpieces, if the dentist uses one for a while (ten minutes is appropriate) replace another one, that is, 2 alternately, this can greatly ease due to "fatigue" and the life from the bearings on the effect. Thus largely extend the life span. According to statistics, almost 60% of the actual bearing is damaged due to the "fatigue".

2. Cleaning and lubrication from the bearing is also an essential.
Cleaning is to avoid foreign matter from entering the bearing and also the bearing inner and external rings with increasing golf ball Mount Sassafras, which is really a detergent and lubricant inside the mobile water and gas foreign currency process. Lubrication is to lessen the ball inside and away from ring and bearing between your Friction forces, making the actual handpiece to high-speed rotator. We want to use within the lubrication oil of professional oil is really a liquid, in the cellular bearing, while a many high-speed rotation loss as well as makes the bearings quickly inside a "dry" state, so to provide before each use with regard to oiling, dental handpiece in the actual lubrication of bearings on time the state.

3. With respect to the brand and model of dental handpiece make use of the appropriate size of the actual drive air pressure.

4. There should be an expert maintenance about three months later while using dental handpiece. This maintenance work is better professionals to operate prior to certain procedures.